NewsEmaZys PV Analyzers Now Available Through Solar Data Systems, Inc. in the...

EmaZys PV Analyzers Now Available Through Solar Data Systems, Inc. in the U.S

The Z200 PV analyzer is a new technology that not only detects plant faults and failures but also pinpoints the exact location of the failure within the array. This unique capability saves an average of 2.5 hours per troubleshooting task.

Growatt

Once connected and activated, the portable, battery-powered instrument will perform impedance spectroscopy between connected string terminals, as well as measure the terminal voltages and currents flowing under various DC loads introduced by the instrument. By combining the results from these various measurements using the on-board computer, critical faults in the system can be defined and located.

“Even in the midst of these precarious times, we strive to keep providing our customers with exceptional products and quality service. Therefore, we are proud to now offer local support for our USA-based customers through the partnership with Solar Data Systems, Inc.,” said Anders Andersen, CEO of EmaZys.

“We focus on being the ultimate Monitoring as a Service provider,” said Silvia Blumenschein, CEO and General Manager of Solar Data Systems. “At Solar Data Systems you get the best of both worlds: a solutions supplier and service provider. We supply the tools needed to monitor solar power and provide needed services to support the growth of solar businesses and solar power. The EmaZys Z200 PV Analyzer was a natural fit for our product portfolio.”

Also Read  Vikram Solar Signs 130 MW Solar Cell Supply Deal to Boost India's Module Manufacturing

Major benefits of the Z200 PV Analyzer include:

  • Dedicated data for fault finding, preventive maintenance & safety
  • Super-fast verification of the PV systems overall health
  • Potential failures can be detected and located in less than 5 minutes
  • PID/TID estimates without dismantling modules
  • Data for the overall health of a PV System, by measuring Rs, Riso, Voc, Isc, system Impedance with and without load, bypass diode test
  • Built-In state machine for easy conclusion on measured data
  • Positioning of Riso faults
  • Positioning of disconnect
  • Tone generator and cable fault finder built-in – up to 1000 V
  • Check of connections, bypass diodes, PID, TID

Discover more from SolarQuarter

Subscribe to get the latest posts sent to your email.

Leave a Reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.

RELATED ARTICLES

Subscribe Today

GET EXCLUSIVE FULL ACCESS TO PREMIUM CONTENT

SUPPORT CLEANTECH JOURNALISM

EXPERT ANALYSIS OF AND EMERGING TRENDS

TOPICAL VIDEO WEBINARS

Get unlimited access to our EXCLUSIVE Content and our archive of subscriber stories.

Exclusive content this week

UPCOMING EVENTS

Latest article

More articles

- Advertisement -Newspaper WordPress Theme