Bangalore Electricity Supply Company Limited (BESCOM) has revised its billing methodology for High Tension (HT) consumers using wheeled solar and non-solar power under the Open Access regime. The revised procedure aims to ensure that energy allocation and Time of Day (ToD) billing comply with Karnataka Electricity Regulatory Commission (KERC) regulations governing banking and electricity consumption across different time slots.

Oriana

In a circular dated November 12, 2026, BESCOM directed its field officers to follow a sequential allocation method for wheeled solar energy instead of the previously used ratio-based approach. The directive is based on the KERC Tariff Order dated March 27, 2025, and the KERC (Terms and Conditions for Open Access) Regulations dated March 26, 2025.

ReNew

Under the KERC framework, HT electricity consumption is classified into four ToD slots. Morning peak hours run from 06:00 to 09:00, day off-peak hours from 09:00 to 18:00, evening peak hours from 18:00 to 22:00, and night off-peak hours from 22:00 to 06:00 the following day.

Since solar generation generally takes place between 09:00 and 15:00, wheeled solar electricity falls entirely within the daytime off-peak category. The Open Access regulations allow banked off-peak energy to be adjusted only against off-peak consumption. Such energy cannot be used to offset electricity consumption during morning and evening peak hours.

BESCOM observed that the earlier ratio-based method distributed wheeled solar and non-solar energy across all four ToD slots according to their share of total monthly consumption. This resulted in some solar energy being adjusted against peak-hour consumption, contrary to the regulatory provisions. Consequently, the method understated BESCOM’s electricity supply during peak hours and affected the calculation of applicable ToD charges.

Under the revised procedure, wheeled solar energy must first be allocated to daytime off-peak consumption, followed by night off-peak consumption. Allocation in each slot will be limited to the actual metered consumption recorded during that period. Any remaining solar energy after meeting both off-peak slots cannot be adjusted against peak-hour consumption and will be treated as BESCOM-supplied energy. Wheeled non-solar energy will be allocated thereafter, with any remaining demand billed as BESCOM supply along with applicable ToD and Open Access charges.

Also Read  CERC Grants 100% ISTS Charge Waiver For 174.9 MW Gujarat Hybrid Project

BESCOM’s illustrative calculation highlights the impact of the change. For a consumer with 56,00,790 metered units, 40,00,000 wheeled solar units and 15,95,000 wheeled non-solar units, the earlier method incorrectly adjusted 11,50,616 solar units against peak slots. Under the revised method, 20,32,920 solar units will be allocated to daytime off-peak consumption and 19,56,780 units to night off-peak consumption. The remaining 10,300 solar units cannot be adjusted, increasing total BESCOM-billed energy to 16,090 units.

The revised methodology will apply from the December 2026 billing month. BESCOM has instructed field offices to review and correct previously issued non-compliant bills and update HT billing software to implement the new allocation procedure.


Discover more from SolarQuarter

Subscribe to get the latest posts sent to your email.

LEAVE A REPLY

This site uses Akismet to reduce spam. Learn how your comment data is processed.

RELATED ARTICLES

Subscribe Today

GET EXCLUSIVE FULL ACCESS TO PREMIUM CONTENT

SUPPORT CLEANTECH JOURNALISM

EXPERT ANALYSIS OF AND EMERGING TRENDS

TOPICAL VIDEO WEBINARS

Get unlimited access to our EXCLUSIVE Content and our archive of subscriber stories.

Exclusive content this week

Latest article

More articles

- Advertisement -Newspaper WordPress Theme